OCU - 9000S
- Cooling power:8000/9000W
- Voltage:Three-phase AC 220/380V
- Installation method:
- Dimensions:H1120xW560xD680mm
- Weight:97kg
Specifications Installing the dimensional
Model | OCU-9000S | |||||||
Cooling Method | Air-Cooled type | |||||||
Performance | Cooling Capacity [W] | 8000/9000 | ||||||
Usable Oil Types | Lube Oil , Hydraulic Mineral Oil | |||||||
Oil Viscosity [mm2/s] | 1.4~200 (ISO GV2~32) | |||||||
Tenperature adjust (Selectable) | Tuning Form | Setting Criteria | Room temperature, Body temperature | |||||
Control Targe | Inlet oil temperature, Outlet oil temperature | |||||||
Tuning Range [℃] | For setting the reference temperature, -19.9 ~ 19.9 | |||||||
Non-removable Type | Control Target | Inlet oil temperature, Outlet oil temperature | ||||||
Control Range[℃] | 5~50 | |||||||
Use Area temperature [℃] | 5~45 | |||||||
Inlet Oil temperature [℃] | 5~50 | |||||||
Electrical characteristics | Rated Voltage [V] | 3AC 220/380V 50Hz | ||||||
Power consumption [W] | 4300 | |||||||
Consumption Current [A] | 13 | |||||||
Transformer capacity [kVA] | 6 | |||||||
Components | Compressor | Swing Type | ||||||
Condenser | Cross-fin Type | |||||||
Evaporator | Shell-end coil Type | |||||||
Fan | Rated output [W] | 100 | ||||||
Oil Pump | Rated output [kW] | 0.7 | ||||||
Oil pump flow rate [L/min] | 30/36 | |||||||
Opening pressure [Mpa] | 0.6 | |||||||
Refrigerant control | Compressor revolutions by inverter + Opening of electric expansion valve | |||||||
Refrigerant | R410A | |||||||
Oil temperature sensor | Thermistor | |||||||
Connecting tube | Oil inlet [RC] | RC1_1/4 | ||||||
Oil outlet [RC] | RC1_1/4 | |||||||
Oil drain [RC] | RC1/4(Plugged) | |||||||
Safety Circuit | Compressor | Temperature protector, Overcurrent relay | ||||||
Refrigeration Cycle | High pressure switch | |||||||
Pump | Overcurrent relay, Relief valve | |||||||
Circuit Board | Fuse | |||||||
Input-Output | Alarm Output | Equipment abnormalities, Condensing temperature anomaly | ||||||
Control input | Remote operation | |||||||
External Thermista | 2W (Optional) | |||||||
RS-232C | RS-232C | |||||||
Noise [dB] | 67 | |||||||
Ingress protection [IP] | IP2X | |||||||
External Dimensions(H×W×D) [mm] | 1120x560x680 | |||||||
Weight [kg] | 97 |
Notes:1.The cooling capacity represents the value at the standard point(inlet oil temperature:35℃,room temperature:35℃,oil for use:ISO VG32).
2. Be sure to use a commercial power supply for the power source.The use of an inverter power supply may cause burn damage to the unit.
3. The yellow line on the tank oil level gauge shows the highest oil level and the red line the lowest oil level.